Deutz 250 m3/h soundproof diesel motor pump unit
EFE-ARD-CO-250-3.5-SS
Performance:- Diesel motor
- Centrifugal, self-priming
- Max flow 550 m3 / h
- HMT 40m
-
Deutz diesel pump unit 250m3/h
EFE-ARD-CO-250-3.5
Performance:- Diesel motor
- Centrifugal, self-priming
- Max flow 550 m3 / h
- HMT: 40m
-
Deutz diesel pump unit 450 m3/h
EFP-ARD-CO-450-3.5
Performance:- Diesel motor
- Centrifugal, self-priming
- Max flow 900 m3 / h
- HMT 38m
-
Deutz 450 m3/h soundproof diesel motor pump unit
EFP-ARD-CO-450-3.5-SS
Performance:- Diesel motor
- Centrifugal, self-priming
- Max flow 900 m3 / h
- HMT 38m
-
Kholer 150 m3/h diesel motor pump unit
EFP-ARD-VA-150-1.5
Performance:- Diesel motor
- Centrifuge, 300 m3/h
- HMT 22m
-
Kholer 150 m3/h soundproof diesel motor pump unit
EFP-ARD-VA-150-1.5-SS
Performance:- Diesel motor
- Centrifugal, self-priming
- Max flow: 300 m3/h
- HMT 22m
-
Yanmar diesel pump unit 250m3/h
EFE-ARD-CO-250-1.5
Performance:- Diesel motor
- Centrifugal, self-priming
- 470 m3 / h
- HMT 18m
-
Yanmar 250m3/h soundproof diesel motor pump unit
EFE-ARD-CO-250-1.5-SS
Performance:- Diesel motor
- Centrifugal, self-priming
- 470 m3 / h
- HMT 18m
-
14kVA Diesel Soundproof Generator Set
EFE-GE16000ST-YW-AVR
Performance:- Power: 14 KVA
- Engine: YANMAR 3TNMA4F
- Fuel: Diesel
- Tank: 55 liters
-
3.3Kw Soundproof Gasoline Generator
EFE-3000IE
Performance:- Max power: 3.3 Kw
- Engine: STAGE V – 4 Stroke
- Fuel
- Tank: 10 liters
-
7.7KVA petrol generator without hood
EFE-GP-8000XT-KE-AVR
Performance:- Power: 7 KVA
- Engine: KHOLER CH440 14c
- Fuel
- Tank: 7 liters
-
8.5Kw petrol covered generator set
EFE-GE85000XT-KE-AVR
Performance:- Power: 8.5Kw
- Engine: Stage V – 4 stroke
- Fuel
- Tank: 28 liters
-
Electric submersible pump
EFP-250-E-VC
Performance:- Self-priming
- Max flow 250 L / min
- Motor speed 2950 rpm
- Discharge connection 50 (2″)
-
Flexible self-rising open tank
PPE-CIT
Performance:- Capacity from 1 to 20m3
- Optimal sealing
- Mechanical resistance
- Fabric 900 gr/m2 PVC
-
Rigid galvanized steel tank
EPI-CIT-GAL-XX
Performance:- Capacity from 1 to 20m3
- Optimal sealing
- Mechanical resistance
- Galvanized steel
-
Flexible fire tanks
EFE-TANK-FLEXIBLE
Performance:- Capacity from 30 to 600 m3
- Durable fabric
- Movable
- 10 years warranty
-
NFPA 20 standard electric pump
EFP-25-6-E
Performance:- 400V electric motor
- Complies with NFPA 20
- Maximum flow of 25 m3 / h
- max head height 60m
-
Fire protection group for building NFPA 20
EFP-130-3
Performance:- 22kW diesel engine
- NFPA20 Compliant
- Max flow of 130m3 / h
- max head height 30m
-
Electropump unit on skid
EFP-20-10
Performance:- Electric motor 18.5 kW
- Complies with NFPA 20
- Max flow 200 m3 / h
- max head height 100m
-
Horizontal pump fire unit
EFP-90-5
Performance:- 42kW diesel engine
- Complies with NFPA 20
- Maximum flow of 90 m3 / h
- max head height 51m
-
Diesel pump set according to NFPA20 standard
EFP-250-12
Performance:- Iveco diesel engine
- Complies with NFPA 20
- Max flow 250 m3 / h
- max head height 122m
-
Horizontal centrifugal pump unit
EFP-500-G
Performance:- Daewoo diesel engine
- Complies with NFPA 20
- Max flow 113.56 m3 / h
- HMT max 182.7 meters
-
Pump unit on frame
EFP-400GPM-4NFPA20
Performance:- Electric motor + diesel
- Complies with NFPA 20
- Max Flow 400GPM
- max head height 40m
-
Diesel engine exhaustion pump
EFP-W30D
Performance:- Diesel heat engine
- Automatic priming
- Max flow 50m³/h
- max head height 26m
-
Agricultural diesel motor pump
EFP-900-2-D
Performance:- Diesel heat engine
- Max flow 1600 l / min
- 900 l / min at 2.4 bar
- 300 l / min at 3 bar
-
4-stroke petrol motor pump
EFP-200-8
Performance:- Petrol petrol engine
- Automatic priming
- Max flow 500 l / min
- max head height 100m
-
Diaphragm pump for contaminated water (10m3 / h max)
EFP-9-0.9
Performance:- HONDA GX160 petrol engine
- Priming: self-priming pump
- Max flow 10m³/h – 167 l/m
- Max pressure: 1.5 bar (15m)
-
High pressure electric test pump for dry columns
EFP-25-0.8BE
Performance:- 230V electric motor
- Max flow 25 l / min
- Pressure gauge from 0 to 50 bar
- Pressure from 0 to 25 bar
-
High pressure thermal test pump for dry columns
VET-25-0.8B
Performance:- Petrol petrol engine
- Manual Start
- Max flow 25 l / min
- Pressure from 0 to 25 bar
-
Self-priming pump for sewage (100m3/h max)
EFP-100-2.8
Performance:- Gasoline or electric diesel engine
- Max flow 96m³/h
- Max pressure 2.8 bar
- 48m³/h at 2 bar
-
Self-priming pump for sewage (144m3/h max)
EFP-144-3
Performance:- Gasoline or electric diesel engine
- Max flow 144m³/h
- 108m³/h at 1.4 bar
- 800m³/h at 2.4 bar
-
Self-priming pump for sewage (51m3/h max)
EFP-51-3
Performance:- Diesel, gasoline or electric engine
- Max flow 48m³/h
- 700 m³/h at 1 bar
- 30 m³/h at 1.7 bar
-
Self-priming gasoline exhaust motor pump
EFP-WP20
Performance:- 4-stroke petrol engine
- Max flow 30 m³
- Maximum pressure 3 bar
- Suction height 7m
-
4-stroke industrial pump
EFP-750-80
Performance:- Petrol petrol engine
- Max flow 750l / min
- 400 l / min at 2.4 bar
- 200 l / min at 2.7 bar
-
Heat pump for intensive work
EFP-150-3-2-ECA
Performance:- Petrol petrol engine
- Max flow 2400l / min
- 1500l / min at 2 bar
- 500 l / min at 1.6 bar
-
Foam concentrate transfer pump with electric motor
EFP-35-17F
Performance:- 230V electric motor
- Corrosion resistant pump body
- Maximum flow of 35 l / min
- Priming up to 2 m
-
Complete trailer for fire intervention
EFP-120-12
Performance:- Flow rate from 120 m3/h to 600 m3/h
- IVECO or other diesel engine
- 40 liter tank
- Installation on trailer
-
Fire intervention trailer equipped with centrifugal pump
EFP-40-30
Performance:- Flow from 40 to 60 m3 / h
- IVECO diesel engine
- 40 liter tank
- Installation on trailer
-
Rigid PVC spiral hose
EFE-PIPE-SPIRALE
Performance:- Temperature range from -5 ° C + 60 ° C
- Inside Ø from 20 to 80 mm
- Weight from 210 to 1450 g / m
-
Rubber fire hoses
EFE-PIPE-ASPIRAL
Performance:- ISO 14557
- AFNOR
- NFS 61113
-
Sea water resistant fire pump
EFP-21K-D-MR
Performance:- Diesel heat engine
- Max flow 1020 l / min
- 800 l / min at 6 bar
- 200 l / min at 13 bar
Good to READ
La fire safety is a crucial element for industrial buildings, as these buildings may contain hazardous materials that can easily cause fires. It is therefore essential to put in place fire prevention and protection measures to protect employees, property and the environment.
Motor pumps play an important role in the fire safety of industrial buildings by providing a means of pumping water to extinguish fires. These pumps can be used to supply the fire fighting systems, such as fire hoses and sprinklers. It is important to ensure that motor pumps are maintained regularly and that employees are trained to use them correctly.
A selection of pumps adapted to your specific needs
Fire safety
Large range of firefighting and flood fighting motor pumps. Pumps can be skid-mounted, portable, or trailer-mounted
Marine - Sea water
Range of motor pumps resistant to sea water. Can be used for security services on ships and oil ports, commercial ports
Industrial building
Fire pumps are usually approved by a certification body and are powered by an electric or diesel engine or sometimes by a steam turbine.
Flood Construction site
Pumps used for lifting wastewater, evacuating loaded and muddy water, drying or irrigating.
Civil security
Motor pumps used during flooding to collect or drain water
Home Security
Motor pumps and a swimming pool to fight fires, as well as our range of cellar pumps intended for the evacuation of rainwater and clear water!